Mitsubishi Electric L26CPU-BT User Manual page 103

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Item
Set the start device where data in RX, RY, RWr, and RWw are
transferred. By setting these items, data in RX, RY, RWr, and
RWw can be automatically transferred to a device in a CPU
Remote Input
module without a program.
(RX)
(1) Number of refresh points
All points for the station number 1 to last station number are
automatically assigned. (Refer to
Appendix 2 (2) and Page 396, Appendix 2 (3).)
To use a different refresh device for each station, transfer the
device individually using a program (Un\G or FROM/TO
Remote
instructions).
Output(RY)
The points for each station can be checked using Device
station offset, size information (buffer memory address: 3E0
to 5DF
(2) Buffer memory areas of the refresh sources
(Refer to
Remote Register
Appendix 2 (3), Page 405, Appendix 2 (10), and Page 407,
(RWr)
Appendix 2 (11).)
• When "Remote Net(Ver.1 Mode)", "Remote Net(Additional
Mode)", or "Remote I/O Net Mode" is set in "Mode", data in the
Ver.1-compatible area are transferred to a CPU module.
• When "Remote Net(Ver.2 Mode)" is set in "Mode", data in the
Ver.2-compatible area are transferred to a CPU module.
(3) To set unique devices
Do not set the same device as the following items:
• Refresh parameters of modules on the network
Remote Register
• I/O numbers used for I/O modules and an intelligent function
(RWw)
module
• Auto refresh settings of an intelligent function module
(4) To set X or Y as a refresh device
Set a unique I/O number used for I/O modules and an
intelligent function module.
(5) Refresh timing
Data are refreshed in the END process of a CPU module.
Ver.2 Remote
When "Remote Net(Additional Mode)" is set in "Mode", set the
Input (RX)
start device where data in RX, RY, RWr, and RWw (Ver.2-
compatible area) of the L series master/local module are
Ver.2 Remote
transferred.
Output (RY)
(1) Number of refresh points
Ver.2 Remote
All points for the start station number to last station number
Register (RWr)
of a Ver.2-compatible device station are automatically
assigned. (Refer to
Page 407, Appendix 2 (11).)
To use a different refresh device for each station, transfer the
data in the devices individually using a program (Un\G or
FROM/TO instructions).
Ver.2 Remote
The points for each station can be checked using Device
Register (RWw)
station offset, size information
(Buffer memory address: 3E0
Page 399, Appendix 2 (4).)
The other contents are same as those for "Remote Input(RX)"
described the above.
Description
). (Refer to
Page 399, Appendix 2 (4).)
H
Page 392, Appendix 2 (2), Page 396,
Page 405, Appendix 2 (10) and
to 5DF
H
H
• Device
X, M, L, B, D, W, R, ZR (X and W for a head
module)
• Device number
Within the device range of the CPU module or
head module
(Default: Blank)
Page 392,
• Device
Y, M, L, B, T, C, ST, D, W, R, ZR (Y and W for a
head module)
• Device number
Within the device range of the CPU module or
head module
H
(Default: Blank)
• Device
M, L, B, D, W, R, ZR (W for a head module)
• Device number
Within the device range of the CPU module or
head module
(Default: Blank)
• Device
M, L, B, T, C, ST, D, W, R, ZR (W for a head
module)
• Device number
Within the device range of the CPU module or
head module
(Default: Blank)
Same as "Remote Input(RX)"
Same as "Remote Output(RY)"
Same as "Remote Register(RWr)"
Same as "Remote Register(RWw)"
) (Refer to
CHAPTER 7 PARAMETER SETTINGS
Setting range
101
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-pbtLj61bt11

Table of Contents