5.2
Applicable System
Applicable programmable controller CPUs and precautions on the system configuration are described below.
5.2.1
Applicable modules and number of connectable modules
(1) Modules applicable to the LJ61BT11, and number of connectable modules
Refer to the following manual.
MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection)
MELSEC-L CC-Link IE Field Network Head Module User's Manual
(2) Compatible software package
Refer to the following manual.
MELSEC-L CPU Module User's Manual (Hardware Design, Maintenance and Inspection)
MELSEC-L CC-Link IE Field Network Head Module User's Manual
(3) Usable device stations
Both of ver.1 and ver.2 compatible device stations can be used.
5.2.2
Restrictions on use with the head module
The following shows the restrictions when using the LJ61BT11 connected to the head module.
(1) "Interrupt Setting" in Network Parameter is not available.
(2) The automatic CC-Link startup function cannot be used.
(3) Dedicated instructions cannot be used.
In addition, the following device stations cannot be connected when parameters are set with dedicated
instructions.
• AJ65BT-R2N
• AJ65BT-D75P2-S3
54