Mitsubishi Electric L26CPU-BT User Manual page 425

Melsec-l cc-link system master/local module
Hide thumbs Also See for L26CPU-BT:
Table of Contents

Advertisement

Number
Name
SW0094
(694
)
H
SW0095
(695
)
H
Transient
*2
transmission status
SW0096
(696
)
H
SW0097
(697
)
H
SW0098
(698
)
H
SW0099
(699
)
H
Station number
*5
overlap status
SW009A
(69A
)
H
SW009B
(69B
)
H
SW009C
(69C
)
H
SW009D
(69D
)
H
Loading/parameter
*5
consistency status
SW009E
(69E
)
H
SW009F
(69F
)
H
Description
Indicates the transient transmission error status.
0: No transient transmission error
1: Transient transmission error occurrence
b15
b14
b13
SW0094
16
15
14
SW0095
32
31
30
SW0096
48
47
46
SW0097
64
63
62
Numbers 1 to 64 in the above table indicate the station numbers.
Reserved stations and any station of the number higher than the max. are excluded.
Even when a dedicated instruction was retried, an error is detected.
Stores the overlap status when the first station number of each module is not
overlapped.
0: Normal
1: Overlap station number (first station number only)
b15
b14
b13
SW0098
16
15
14
SW0099
32
31
30
SW009A
48
47
46
SW009B
64
63
62
Numbers 1 to 64 in the above table indicate the station numbers.
Reserved stations and any station of the number higher than the max. are excluded.
Unable to detect station number overlapping of standby master stations.
For the device stations with "Auto-tracking" set for transmission speed, station
numbers may not be detected even when any of them are overlapping.
Stores the consistency status between the loaded station and the parameter settings.
A matching error occurs in any of the following cases.
1) Station type mismatch *
2) Number of occupied stations mismatch
3) Expanded cyclic setting mismatch *
4) CC-Link compatible version mismatch
* A matching error will not occur when installation  parameter. (For example, a
matching error will not occur when a remote device station is installed and the
parameter setting is an intelligent device station.)
0: Normal
1: Matching error
Example of matching error
Installation
Remote device station
Intelligent device station
b15
b14
b13
SW009C
16
15
14
SW009D
32
31
30
SW009E
48
47
46
SW009F
64
63
62
Numbers 1 to 64 in the above table indicate the station numbers.
Reserved stations and any station of the number higher than the max. are excluded.
to
b12
b3
b2
b1
13
to
4
3
2
29
to
20
19
18
to
45
36
35
34
61
to
52
51
50
b12
to
b3
b2
b1
13
to
4
3
2
to
29
20
19
18
45
to
36
35
34
61
to
52
51
50
Parameter
Remote I/O station
Remote I/O station
Remote device station
to
b12
b3
b2
b1
13
to
4
3
2
to
29
20
19
18
to
45
36
35
34
61
to
52
51
50
APPENDICES
Availability
(: Available, : Not
available)
Online
Master
Local
station
station
b0
1
17
33
49
b0
1
17
33
49
b0
1
17
33
49
A
Offline
423

Advertisement

Table of Contents
loading

This manual is also suitable for:

L26cpu-pbtLj61bt11

Table of Contents