Installing a rear 2 SFF SAS/SATA drive cage over the power supplies

Installing a rear 2 SFF SAS/SATA drive cage over the power supplies
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
The components included with the hardware option kit
The front bays are fully populated with 12 LFF or 24 SFF drives
High-performance fans are installed in all fan bays
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Do one of the following:
If installed, remove the secondary riser cage.
Remove the secondary wall blank.