Installing a front 8NVMe drive cage

Installing a front 8NVMe drive cage
Prerequisites
Prerequisites
High-performance fans are required when installing this option.
About this task
About this task
The drive cage can be installed in any box. This procedure covers installing the drive cage in box 1.
Procedure
Procedure
1. Observe the following alerts.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
WARNING:
components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation
CAUTION:
procedure. Improper grounding can cause ESD.
2. Power down the server.
3. Do one of the following:
Extend the server from the rack .
Remove the server from the rack .
4. Remove the access panel .
5. Remove the air baffle .
6. Remove the fan cage.
7. Remove the blank.
8. Install the drive cage:
a. Remove all drive blanks .
b. Install the drive cage.