Installing A Dimm Blank - HPE ProLiant DL380 Gen10 Plus User Manual

Table of Contents

Advertisement

Installing a DIMM blank

Installing a DIMM blank
About this task
About this task
Use the following table to decide if the thermal restrictions of the server require DIMM blanks in all open slots of your configuration.
Processor TDP
Processor TDP
DIMM blank installation
DIMM blank installation
105W to 140W
Recommended
230W to 270W
Recommended
150W to 270W
Required
Procedure
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
a. Extend the server from the rack .
b. Remove the server from the rack .
4. Remove the access panel .
5. Open the DIMM slot latches.
6. Install the DIMM blank.
Installing a DIMM blank
114