Fan options

Fan options
CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-processor
CAUTION:
configuration.
CAUTION: To avoid damage to the equipment, do not operate the server for extended periods of time if the server does
CAUTION:
not have the optimal number of fans installed. Although the server might boot, Hewlett Packard Enterprise does not
recommend operating the server without the required fans installed and operating.
Valid fan configurations are listed in the following table.
Configuration Fan bay 1
Configuration
Fan bay 1
1 processor
Fan blank
1 processor
Fan
24-SFF or
12-LFF
configuration
with high-
performance
fans
2 processors Fan
For a single-processor configuration, excluding 24-SFF and 12-LFF configurations, four fans and two blanks are required in specific fan
bays for redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan causes an orderly
shutdown of the server.
For a dual-processor configuration or single-processor 24-SFF or 12-LFF configurations, six fans are required for redundancy. A fan
failure or missing fan causes a loss of redundancy. A second fan failure or missing fan causes an orderly shutdown of the server.
High-performance fans might be necessary in 24-SFF and 12-LFF configurations for the following installations:
Optional GPU riser installations
ASHRAE compliant configurations
For more information, see the Hewlett Packard Enterprise website
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change requires a fan speed increase to
cool the server. The server shuts down during the following temperature-related scenarios:
At POST and in the OS, iLO performs an orderly shutdown if a cautionary temperature level is detected. If the server hardware
detects a critical temperature level before an orderly shutdown occurs, the server performs an immediate shutdown.
When the Thermal Shutdown feature is disabled in the BIOS/Platform Configuration (RBSU), iLO does not perform an orderly
shutdown when a cautionary temperature level is detected. Disabling this feature does not disable the server hardware from
performing an immediate shutdown when a critical temperature level is detected.
CAUTION: A thermal event can damage server components when the Thermal Shutdown feature is disabled in the
CAUTION:
BIOS/Platform Configuration (RBSU).
Subtopics
Subtopics
Installing high-performance fans
Installing high-performance fans
Fan bay 2
Fan bay 2
Fan bay 3
Fan bay 3
Fan blank
Fan
Fan
Fan
Fan
Fan
Hewlett Packard Enterprise website .
Fan bay 4
Fan bay 4
Fan bay 5
Fan bay 5
Fan
Fan
Fan
Fan
Fan
Fan
Fan bay 6
Fan bay 6
Fan
Fan
Fan
Fan options
124