Installing a rear 2SFF SAS/SATA drive cage over the power supplies

Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-10 Torx screwdriver
The components included with the hardware option kit
The front bays are fully populated with 12 LFF or 24 SFF drives
High performance fans are installed in all fan bays
Procedure
1.
Power down the server.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack .
4.
Remove the access panel.
5.
Do one of the following:
If installed, remove the secondary riser cage.
Remove the secondary wall blank.
Hardware options installation