Fan options

CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-
processor configuration.
CAUTION: To avoid damage to the equipment, do not operate the server for extended periods of time if the server
does not have the optimal number of fans installed. Although the server might boot, Hewlett Packard Enterprise
does not recommend operating the server without the required fans installed and operating.
Valid fan configurations are listed in the following table.
Configuration
1 processor
1 processor 24-SFF or
12-LFF configuration
with high-performance
fans
2 processors
For a single-processor configuration, excluding 24-SFF and 12-LFF configurations, four fans and two blanks are required
in specific fan bays for redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or
missing fan causes an orderly shutdown of the server.
For a dual-processor configuration or single-processor 24-SFF or 12-LFF configurations, six fans are required for
redundancy. A fan failure or missing fan causes a loss of redundancy. A second fan failure or missing fan causes an orderly
shutdown of the server.
High-performance fans might be necessary in 24-SFF and 12-LFF configurations for the following installations:
Fan bay 1
Fan bay 2
Fan blank
Fan blank
Fan
Fan
Fan
Fan
Fan bay 3
Fan bay 4
Fan
Fan
Fan
Fan
Fan
Fan
Hardware options installation
Fan bay 5
Fan bay 6
Fan
Fan
Fan
Fan
Fan
Fan