Webasto ProCore Edge Installation, Operation, Service And Maintenance Instructions page 58

Table of Contents

Advertisement

Installation, Operations, Service & Maintenance
Display
Message
(Name)
Charger
Configuration
Access
Current Control
DC Line Open
Duplicate
Module IDs
Factory Data
Not Set
Fan Speed Low
Fan Speed Too
Low
Module General
Fault
Module High
Temperature
Part Number 5911110 A02
Message
Description
type
The charge could not
read charge configuration
Fault
settings.
One or more power
Warning
modules are not delivering
current.
The difference between the
module reported voltage
Fault
and local battery voltage
exceeds 5 volts.
At least two modules have
Fault
duplicate CAN IDs on the
internal CAN bus.
The charger factory config-
Fault
uration is missing.
Warning
The fan speed is very low.
The fan has stopped or is
Warning
too low to charge.
The module faulted with no
Fault
specific reason reported.
The module temperature is
Warning
very high
Page 58 of 112
ProCore Edge
Action(s)
Call Webasto service.
Call Webasto service.
Check the battery voltage
sensor wiring for damage.
Call Webasto service.
Call Webasto service.
Call Webasto service.
Call Webasto service.
Call Webasto service.
Check for obstructed air
flow.
Webasto Charging Systems, Inc.