Installation, Operations, Service & Maintenance
Connection and Description – 10-Bay Cabinets
The table below describes the bare-ended signal connections that can be con-
nected to the charger via this connector.
Connection
Pin 12
Pin 11
Pin 10
Pin 9
Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2
Pin 1
The connector can accept up to a 16 AWG wire.
CAUTION
Use only copper wires.
Part Number 5911110 A02
Description
PILOT (GREEN) (BAT CON 2)
PILOT RETURN (BLACK) (BAT CON 2)
CANH/DATA (RED) (BAT CON1)
CANL/DIR (WHITE) (BAT CON2)
PILOT (GREEN) (BAT CON 1)
PILOT RETURN (BLACK) (BAT CON 1)
SWA and SWB (DCT pins 6 and 5, respectively) are
for an external pilot interlock connection. These pins, in
order to charge, must be shorted either by a normally
closed external interlock or jumper. A jumper between
these pins is factory installed to ensure that the unit
operates when it reaches a destination.
Negative lead connecting and controlling the 24VDC
WATERING VALVE
Positive lead connecting the 24VDC WATERING
VALVE
Negative lead to the SPARE RELAY
Positive lead to the SPARE RELAY