Webasto ProCore Edge Installation, Operation, Service And Maintenance Instructions page 34

Table of Contents

Advertisement

Installation, Operations, Service & Maintenance
Use the appropriate minimum wire size (gauge) or larger for the maximum
kilowatt rating of the charger. See section 3 for the minimum fitted AC input wire
size (AWG) per NEC.
The AC service entrance provides two-hole sizes.
1. Use the provided round panel to use the smaller hole size, or remove this
panel to use the larger hole size.
2. Place an appropriate cable gland or conduit clamp in this AC service en-
trance to secure the cable or conduit.
3. Connect the three-phase AC input power cables.
Ensure that ground and power cables have been properly stripped of approx-
imately 0.5 in. (12.7 mm) of insulation from the ends. Loosen the AC input
terminal screws, with a flathead screwdriver, and insert the stripped ends of the
ground and power cables.
4. Re-tighten the screws with a minimum to maximum of 23 in-lbs
(2.6 Nm) to 26 in-lbs (2.9 Nm) of torque, respectively. AC line input positions
are interchangeable because the three-phase input is not phase specific.
5. Ensure that the cable gland or conduit clamp has been properly tightened.
Part Number 5911110 A02
Page 34 of 112
ProCore Edge
Webasto Charging Systems, Inc.