Webasto ProCore Edge Installation, Operation, Service And Maintenance Instructions page 56

Table of Contents

Advertisement

Installation, Operations, Service & Maintenance
Display
Message
(Name)
BATT UNDER
VOLTAGE
(Battery under
voltage)
Battery
Communication
Timeout
Battery
Connection
Issue
Battery Data
Invalid
Part Number 5911110 A02
Message
Description
type
The battery voltage is too
low to start the fast charge
(the voltage is below the
battery table minimum
voltage limit).
The battery is drained to a
voltage below a safe level
for charging. Recovery
charge is needed.
Fault
The battery voltage is too low
(i.e., below the operational
voltage limit) to use on this
charger
The BMID number of
battery cells setting is
incorrect.
Communication with the
Fault
battery was lost over the
communication bus.
Battery initialization failed
Fault
during connection.
The BMID configuration
Fault
data read from the battery
are not valid for the charge.
Page 56 of 112
ProCore Edge
Action(s)
Press and hold the EQ
Schedule button to initiate
a recovery charge and
raise safely the battery
voltage.
Use a charger that supports
the battery voltage.
Use the ProCore™ App
BMID setup to set the
correct number of
battery cells.
Check the communication
wires.
Check the battery
communications wiring
for damage.
Use the ProCore App to
recheck the battery
parameters in the BMID.
Webasto Charging Systems, Inc.