Webasto ProCore Edge Installation, Operation, Service And Maintenance Instructions page 111

Table of Contents

Advertisement

ProCore Edge
6.
Run BL_CAN_v2.15.0.exe.
7.
Record the first variant, which indi-
cates the bootloader revision(s).
8.
Record the second variant, which
indicates the application version(s).
WARNING: If any bootloader is <
00.02.02.00, take a screen shot of
the BL_CAN output and forward it
to the responsible SW engineer. DO
NOT PROCEED WITH THE FIRM-
WARE UPDATE.
9.
Drag the relevant binary file onto
BL_CAN_v2.15.0.exe 80V mod-
ules PM3K-80_PWM_v1.14.0.dfu
and 48V models PM3K-48_PWM_
v1.14.1.dfu.
10. Check to see if the binary file is
valid – the update will proceed on all
connect modules simultaneously.
11. With the update complete, discon-
nect the PCAN from the module,
then reconnect the ribbon cable/
CAN connector to J4 on the System
Controller.
12. On Tera Term, type in PM and select
Enter – this will display the power
module information. The software
version displayed should be 1.14.0.
NOTE: The module type and serial
number displayed varies, depending
on the ProCore Edge 48V or 80V.
Webasto Charging Systems, Inc.
Installation, Operations, Service & Maintenance
Page 111 of 112
Part Number 5911110 A02