Oce Arizona 365 GT User Manual page 196

Table of Contents

Advertisement

Fill the Coolant Reservoir
Illustration
[140] Fill Coolant Reservoir
Procedure
1. Open the container of coolant fluid.
2. Insert the syringe into the fluid and draw back the plunger until the syringe is almost full (leave a
small amount of air so that you can expel it at the end to avoid fluid dripping from the fill nozzle.
3. Wipe any excess fluid from the hose attached to the syringe (if the hose is wet it is difficult to
perform the next step).
4. Insert the hose into the fill nozzle above the coolant level tube.
5. Press on the syringe plunger to inject the fluid. Inject the entire contents of the syringe. Repeat, if
necessary, until the coolant level is above the halfway point on the sight tube.
NOTE
Do not overfill the coolant as this can cause temperature variations. If the coolant does
not flow into the fill nozzle the printer may have a defective nozzle and this will require
a service call.
6. Remove the hose and store the syringe and the coolant fluid container until it is needed again.
196
Chapter 11 - Printer Maintenance

Advertisement

Table of Contents
loading

Table of Contents