8-1

Status Monitors

This section describes the output frequency, fault monitor during trip, and other monitor functions of
the inverter.
8-1-1

Operation Monitor

Parameter No.
3010Hex-04Hex
3017Hex-10Hex
3010Hex-06Hex
3010Hex-07Hex
3010Hex-08Hex
3010Hex-03Hex
M1 Series EtherCAT Type User's Manual (I670)
Item
Output Frequency Moni-
0.00 to 590.00
tor before Slip Compen-
[Hz]
sation
Output Frequency After
0.00 to 590.00
Slip Compensation
[Hz]
Output Current Monitor
0.00 to 655.3 [A]
Output Voltage Monitor
0.0 to 999.0 [V]
Output Torque Monitor
-400 to 400 [%]
Frequency Reference
0.00 to 590.00
Monitor
[Hz]
Range
Output frequency 1 (before slip com-
pensation) is displayed in increments of
0.01 Hz.
Output frequency 2 (after slip compen-
sation) is displayed in increments of
0.01 Hz.
Output current effective value is dis-
played in increments of 0.01 A.
A current value of 100 A or higher is
displayed in increments of 0.1 A.
The output voltage command value is
displayed in increments of 0.1 V.
However, the display value changes in
increments of 1.0 V.
The torque calculated value, torque
command value and torque current
command value are displayed in incre-
ments of 1%.
Rated motor torque ratio of torque
calculated value in the case of V/f
control and dynamic torque vector
control
Speed control mode of vector control:
Rated motor torque ratio of speed
control output (after torque bias)
When the torque command is used in
the torque control mode of vector
control: Rated motor torque ratio of
torque command value
When the torque current command is
used in the torque control mode of
vector control: Rated motor current
ratio of torque current command val-
ue
Displays the set frequency in incre-
ments of 0.01 Hz.
8 Other Functions
Display item
8-3
8