U: Monitor Parameters; U: Monitor Parameters; U1: Operation Status Monitors; U2: Fault History - Omron JZA User Manual

Compact general purpose inverter 200 v class three-phase input 0.1 to 0.4 kw 200 v class single-phase input 0.1 to 1.5 kw 400 v class three-phase input 0.2 to 4.0 kw
Hide thumbs Also See for JZA:
Table of Contents

Advertisement

5.10 U: Monitor Parameters

5.10 U: Monitor Parameters

Monitor parameters let the user view various aspects of drive performance as it is shown on the operator display.
Some monitors can be output from terminal AM by assigning the specific monitor parameter number to H4-01.
H4-01: Multi-Function Analog Terminal AM Monitor Selection on page 101
analog output.
u

U1: Operation Status Monitors

Status monitors display drive status like output frequency, current etc. Refer to U1: Operation Status Monitors on page
181
for a complete list of U1- monitors and descriptions.
u

U2: Fault History

The fault history monitors can be used to view the current and the last occurred fault. Refer to U2: Fault History on page
182
for a list of U2- monitors and descriptions.
U2- monitors are not reset when the drive is initialized.
to initialize the fault history.
u

U4: Maintenance Monitors

Maintenance monitors show:
• Runtime data of the drive.
• Maintenance data and replacement information for various drive components.
• Highest peak current that has occurred and output frequency at the time the peak current occurred.
Refer to U4: Maintenance Monitors on page
116
Refer to o4-11: U2 Initialization on page 115
182
for a complete list of U4- monitors and descriptions.
for details on assigning functions to the
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Refer to
for instructions

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jza j1000

Table of Contents