Event name
Inverter Overheat Error
Meaning
The inverter's internal temperature exceeded the allowable range.
Source
EtherCAT Master Function Mod-
ule
Error attrib-
Level
utes
Effects
User program
Indicators
EtherCAT NET RUN
---
System-de-
Variable
fined varia-
None
bles
Cause and
Assumed cause
correction
(1) The inverter's ambient tem-
perature exceeds the specified
range.
Attached in-
None
formation
Precautions/
None
Remarks
A-242
Source details Slave
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
None
Correction
Measure the ambient tempera-
ture.
→ Lower the ambient tempera-
ture of the inverter, for example,
by improving the ventilation in
the panel.
Event code
08810000 hex
Detection tim-
ing
Error reset
Log category
Motor stops.
EtherCAT LINK/ACT
---
Name
None
Prevention
Examine the ambient tempera-
ture of the inverter and provide
the necessary cooling.