Drive Programming
POS
Description
Current Position
(d030)
monitor
The data referenced with this variable corresponds to the data monitored by the current position
monitor (d030).
With RX when "03" (high-resolution absolute position control) has been selected for control pulse
setting (P012), the range in brackets "[]" applies.
ERR-
Description
CNT
(d080)
Trip counter monitor
The data monitored with this variable corresponds to the data monitored by the trip counter monitor
(d080).
ERR(1)-
Description
ERR(6)
(d081-
Trip monitor 1 to 6
d086)
The data monitored with these variables correspond to the data monitored by trip monitors 1 to 6
(d081 to d086).
DCV
Description
(d102)
DC voltage monitor
The data referenced with this variable corresponds to the data monitored by the DC voltage monitor
(d102).
STATUS
Description
Inverter status monitor
This variable can be used to reference inverter status information.
The information is reflected with the following bit weights:
Bit 9
Bit 8
Bit 7
to 15
Under
Reserve
Reset
voltage
Range of values
28
28
- (2
- 1) to 2
30
30
[- (2
- 1) to 2
Range of values
0 to 65535
Range of values
0 to 127
Range of values
0 to 9999
Range of values
-
Bit 6
Bit 5
Over voltage
Over current
suppression
suppression
Default
Unit
- 1
-
1
- 1]
Default
Unit
Nº of
-
times
Default
Unit
-
-
Default
Unit
0.1
-
Vdc
Default
Unit
-
-
Bit 4
Bit 3
Overload
Retry
suppression
28
Data size
Attribute
Signed
R
2-word
Data size
Attribute
Unsigned
R
1-word
Data size
Attribute
Unsigned
R
1-word
Data size
Attribute
Unsigned
R
1-word
Data size
Attribute
Unsigned
R
1-word
Bit 2
Bit 1
Bit 0
Reverse
Trip
Run