Alarm Information - Omron M1 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

8 Other Functions
Parameter No.
3017Hex-50Hex
8-1-4

Alarm information

Parameter No.
1 Latest alarm
3011Hex-15Hex
3011Hex-16Hex
3011Hex-17Hex
3011Hex-18Hex
3011Hex-19Hex
3011Hex-1AHex
3011Hex-1BHex
8-16
Item
Total RUN Time Monitor
Item
Latest Alarm Info. Output
Frequency
Latest Alarm Info. Output
Current
Latest Alarm Info. Output
Voltage
Latest Alarm Info. Torque
Monitor
Latest Alarm Info. Fre-
quency Command
Latest Alarm Info. Running
Status 1
Latest Alarm Info. Cumula-
tive Ope. time
Range
The cumulative time of the inverter
RUN state is displayed.
0 to 655350 hours
Measurement range: 0 to 655350 hours
If 655350 hours is exceeded, the accu-
mulation operation stops.
Range
The output frequency before slip com-
0.00 to 99.99,
pensation is displayed in increments of
100.0 to 590.0
0.01 Hz. A value of 100.0 Hz or higher
[Hz]
is displayed in increments of 0.1 Hz.
The output current is displayed. A cur-
0.00 to 99.99,
rent value of 100.0A or higher is dis-
100.0 to 655.3 [A]
played in increments of 0.1 A.
Display unit: A (Ampere)
The output voltage is displayed.
0 to 999 [V]
Display unit: V (Volt)
The torque calculated value is dis-
-400 to 400 [%]
played.
0.00 to 99.99,
100.0 to 590.0
The set frequency is displayed.
[Hz]
The operation status is displayed by a
four-digit hexadecimal.
0000 to FFFF hex
Bit 15: BUSY (During function code da-
ta writing)
Bit14: -
Bit13: -
Bit12: RL (Communications effective)
Bit11: ALM (Alarm relay)
Bit10: DEC (During deceleration)
0000Hex to
Bit9: ACC (During acceleration)
FFFFHex
Bit8: IL (During current limiting)
Bit7: VL (During voltage limiting)
Bit6: TL (Torque limiting)
bit5: NUV (Main circuit DC voltage es-
tablished)
Bit4: BRK (During braking)
Bit3: INT (Inverter shut down)
Bit2: EXT; During DC braking or during
pre-exciting
Bit1: REV (During reverse operation)
Bit0: FWD (During forward operation)
The cumulative inverter run time (the
0 to 655,350 hours
time when the main power supply is
ON) when an error occurs is displayed.
M1 Series EtherCAT Type User's Manual (I670)
Display item
Display item

Hide quick links:

Advertisement

Table of Contents

Troubleshooting