Event code
Event name
684A0000 hex
Low Torque
Detected
684B0000 hex
Motor Run
Time Over
684C0000 hex
Number of
Startups
Over
684D00000 hex
PTC Ther-
mistor Error
96530000 hex
Communica-
tion Timeout
with Sysmac
Studio
A-218
Description
The output torque re-
(1) Low torque detected
mained below the de-
tection level for more
than the detection
time.
The cumulative run
(1) Motor run time over
time of the motor
reached the set time
for maintenance.
The cumulative num-
(1) Number of Startups Over
ber of startups of the
motor reached the set
count for mainte-
nance.
The PTC thermistor
(1) The motor's ambient tem-
detected a tempera-
perature exceeds the specified
ture not less than the
range.
set temperature.
(2) The motor's cooling sys-
tem failed.
(3) The load is large.
(4) The value of 1st
Thermistor Error Detection
Level (3008-1C hex) is not ap-
propriate.
(5) The PTC thermistor set-
tings are not appropriate.
(6) The value of 1st Manual
Torque Boost Voltage
(3004-0A hex) is too high.
(7) The V/f settings are incor-
rect.
(8) There is an incorrect pa-
rameter setting.
A communication
(1) A communications cable is
timeout occurred in
broken.
the connection be-
tween Sysmac Studio
and the Safety CPU
Unit.
Assumed cause
Min
M1 Series EtherCAT Type User's Manual (I670)
Level
Reference
Obs
Info
page
A-282
page
A-282
page
A-283
page
A-284
page
A-285