A-4-9 H Group Parameter List (High Level Functions - Omron M1 Series User Manual

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

A-4-9
H Group Parameter List (High Level Functions)
Sub-
Pa-
Index
index
rame-
(hex)
(hex)
ter No.
3008
04
H03
Data Initialization
05
H04
Retry Count at
Trip
06
H05
Retry Standby
Time at Trip
07
H06
Cooling Fan
Function Selec-
tion
08
H07
Acceleration/
Deceleration Pat-
tern Selection
09
H08
Reverse Rotation
Prevention Func-
tion
M1 Series EtherCAT Type User's Manual (I670)
Function name
Monitor or data range
V/f
DTV
SLV
PGV PM SLV PM PGV
0: Disable
1: Initialize all parameters
2: Initialize motor 1 parameters
3: Initialize motor 2 parameters
4: Restore user defined data
5: Initialize all parameters (except I/O
and communications)
6: Reserved
7: Clear alarm history
8: Clear selection of favorite function
code
V/f
DTV
SLV
PGV PM SLV PM PGV
0: Disable
1 to 20: Number of retries
V/f
DTV
SLV
PGV PM SLV PM PGV
0.5 to 20.0
V/f
DTV
SLV
PGV PM SLV PM PGV
0: Always Fan ON
1: ON/OFF control effective
V/f
DTV
SLV
PGV PM SLV PM PGV
0: Disable (Linear acceleration/decel-
eration)
1: S-curve acceleration/deceleration
(Weak)
2: S-curve acceleration/deceleration
(Arbitrary: According to H57 to H60)
3: Curve acceleration/deceleration
V/f
DTV
SLV
PGV PM SLV PM PGV
0: Disable
1: Reverse rotation inhibited
2: Forward rotation inhibited
Default
data
0
PG V/f PG DTV
0
PG V/f PG DTV
5
PG V/f PG DTV
0
PG V/f PG DTV
0
PG V/f PG DTV
0
PG V/f PG DTV
Appendices
Set-
ting
PDO
dur-
Unit
map
ing
RUN
---
---
Possible
---
Possible
s
Possible
---
Possible
---
Possible
---
---
Possible
A-133
A

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents