Macrok -- Delete One Or All Macros; Macrol -- List All Commmands In A Macro - Polycom Vortex EF2241 Programming Manual

Rs-232 command set
Hide thumbs Also See for Vortex EF2241:
Table of Contents

Advertisement

generated if the specified command is valid, but its data is invalid. For example:
B01MACROA25,LAYDOWNTHEBOOGIE
Would return an error because it does not contain a valid command. However:
B01MACROA62,MUTEOMYMOTHERINLAW
Would not return an error because it contains a
macro is executed with a
strange data.
The proper sequence for creating a macro (macro number 112 in this example) is as follows.
B01MACROS112
B01MACROA112,MUTEI*0
B01MACROA112,GAINI*0
B01MACROA112,MUTEO*0
B01MACROW112
This defines macro number 112 to unmute all inputs, set all input gains to 0 dB, and unmute all outputs. It is
acceptable if another command is sent in between these commands (such as B01NC*? ) as long as it isn't
another non-volatile memory command which could interfere with the storage of the macro.

8.96. MACROK -- Delete One or All Macros

This command kills (deletes) the specified macro. If the wildcard character (*) is used the specify the macro
number, then all macros are deleted. Deleting all macros via MACROK* is more efficient than deleting them
all individually since it requires less writes to non-volatile memory.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each
time it is changed. It will retain its value after power-down. Since this command writes to non-volatile
memory, there will be a delay before an acknowledgment is returned.
Example
Description
Delete all the commands associated with macro number 25.
B01MACROK25
Delete all the commands associated with all 255 macros.
B01MACROK*

8.97. MACROL -- List All Commmands in a Macro

This command lists all the commands in a given macro. For example, assume that a macro has been defined
via the following command sequence.
B01MACROS112
B01MACROA112,MUTEI*0
B01MACROA112,GAINI*0
or
command and it tries to execute the
MACROX
MACROQ
command. An error would be returned when the
MUTEO
command with
MUTEO
Status Message
B01MACROK25
B01MACROK*