(input1, input A, and input B are unmuted) AND
(input C OR input D is muted)
An error condition of ERROR#074 will be generated if the assigned command is invalid.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each
time it is changed. It will retain its value after power-down. Since this command writes to non-volatile
memory, there will be a delay before an acknowledgment is returned.
Example
B01LOA10,MUTEI*10++--..
B01LOA7,
8.90. LOD -- Define Behavior for Logic Output Deactivated
Status
This command is used to define the conditions under which a given logic output pin goes into the deactive
state. The syntax and behavior of this command is identical to that of the
description of the
LOA
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved each
time it is changed. It will retain its value after power-down. Since this command writes to non-volatile
memory, there will be a delay before an acknowledgment is returned.

8.91. LOEN -- Enable Automatic Logic Output Status Messages

This command controls whether or not logic output status messages are sent automatically. If LOEN is
enabled, then a logic output query (LO*?) is performed any time any of the states change on the logic
output pins. For example, if all logic outputs are currently in the low state ('0') and LOEN is enabled, then if
logic output 12 changes state to '1', the following status message will be generated:
B01LO*00000000000100000000
A status message is only generated if there is a state change. This helps keep data traffic to a minimum.
This command is a boolean command. See
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description
B01LOEN1 Enable automatic logic output status messages. B01LOEN1
B01LOEN0 Disable automatic logic output status messages. B01LOEN0
Description
Configure the conditions for activation of
logic output 10 as described in the
example above.
Delete conditions for activation of logic
output 7.
command for more information, including examples.
Section 6.1
LOA
for more information on this type of command.
Status Message
Status Message
B01LOA10,MUTEI*10++--..
B01LOA7,
command. Please refer to the