Set microphone 4 as the chairman mic
B01AMCHNUM14
for automixer 1.
Set microphone 1 as the chairman mic
B01AMCHNUM21
for automixer 2.
Query the current chairman mic for
B01AMCHNUM1?
automixer 1.
8.16. AMDECAY -- Set Decay Time for Automixers
This command sets or queries the decay time (in milliseconds) for both automixers. Note that the decay time
is set globally for both automixers.
This command is an integer command. See
minimum and maximum values for this command are 0 and 5000, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
Set automixer decay time to 500
B01AMDECAY500
ms.
Increase automixer decay time by
B01AMDECAY>500
500 ms.
Query automixer decay time.
B01AMDECAY?
8.17. AMGATEC -- Set Automixer Gating Control Mode
This command sets the automixer gating control mode for the specified input channel. The possible modes
are:
0 - normal gating
1 - microphone forced on
2 - microphone forced off
This command is a channel integer command. See
type of command. The minimum and maximum values for this command are 0 and 2, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
B01AMCHNUM14
B01AMCHNUM21
B01AMCHNUM1x , where x is between 1 and 8
depending on the current chairman mic setting
for automixer 1.
Section 6.2
for more information on this type of command. The
Status Message
B01AMDECAY500
B01AMDECAYx , where x is between 0 and 5000
depending on the current AMDECAY setting. If this
command is issued after the above example, then
the status message will be B01AMDECAY1000
B01AMDECAYx , where x is between 0 and 5000
depending on the current AMDECAY setting. If this
command is issued after the above example, then
the status message will be B01AMDECAY1000