Ahcp -- Enable Or Disable Call Progress Based Auto Hangup - Polycom Vortex EF2241 Programming Manual

Rs-232 command set
Hide thumbs Also See for Vortex EF2241:
Table of Contents

Advertisement

'B01AGCRATET10', 'B01AGCRATET?').
This command is a channel integer command. See
type of command. The minimum and maximum values for this command are 1 and 5, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
B01AGCRATE13
B01AGCRATET?
B01AGCRATE*5
B01AGCRATE*ààêê
B01AGCRATE*?
8.9. AHCP -- Enable or Disable Call Progress Based Auto
Hangup
This command sets or queries the status of the call progress based auto hangup feature. There are two
methods of auto hangup supported: call progress and loop drop. The call progress method listens for off-
hook or busy tones and hangs up the phone if they are detected. The loop drop method looks for a drop in
loop current on the phone line and hangs up the phone if a loop current drop is detected. The AHCP
command controls the call progress auto hangup feature. The
hangup feature. These two features are controlled and implemented independently.
This command is a boolean command. See
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description
B01AHCP1 Enable call progress based auto hangup mode. B01AHCP1
B01AHCP0 Disable call progress based auto hangup mode. B01AHCP0
B01AHCP2 Toggle call progress based auto hangup mode.
Description
Set AGC ramp rate on input
channel 1 to 3 dB/sec.
Query the AGC ramp rate on
input channel T .
Set AGC ramp rate on input
channels 1-4 to 5 dB/sec.
Set AGC ramp rate on input
channels 1-2 to 1 dB/sec and
AGC ramp rate on input
channels 3-4 to 4 dB/sec.
Query AGC ramp rate on input
channels 1-4.
Section 6.1
Section 6.3
and
Section 6.2
Status Message
B01AGCRATE13
B01AGCRATETx where x is a number between 1
and 5, depending on the current setting of the AGC
ramp rate on input channel T .
B01AGCRATE*ëëëë
B01AGCRATE*ààêê
B01AGCRATE*abcd, where a-d are each between à
and ë, depending on the current setting of the AGC
ramp rate for each of the four input channels.
command controls the loop drop auto
AHLD
for more information on this type of command.
Status Message
B01AHCPx , where x is 0 or 1 depending on
the current state of the call progress based
auto hangup mode.
for more information on this

Advertisement

Table of Contents
loading