information. To set the frequency parameter for an input parametric EQ filter, use the
set all the parameters for an input parametric EQ filter, use the
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
B01PEQOF3,2,1250
B01PEQOFB,1,?
8.129. PEQOG -- Set Gain Parameter for Specified Parametric
EQ Output Stage
This command sets or queries the gain parameter (in dB) for the parametric equalizer (EQ) filters on output
channels 1-4, A-D, T, and L . Each channel has five bands of parametric EQ that can be independently
controlled.
The minimum and maximum values for the gain parameter are -20 and 20, respectively.
This command has the same format and restrictions as the
parameter, the gain, is specified instead of all the parameters. See the
information. To set the gain parameter for an input parametric EQ filter, use the
the parameters for an input parametric EQ filter, use the
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
B01PEQOG3,2,-20
B01PEQOGB,1,?
8.130. PEQOS -- Set Slope Parameter for Specified Parametric
EQ Output Stage
Description
Set frequency of parametric EQ
on output 3 , band 2 to 1250
Hz.
Query current frequency
setting of parametric EQ on
output B , band 1.
Description
Set the gain of the parametric EQ
on output 3 , band 2 to -20 dB.
Query current gain setting of
parametric EQ on output B , band 1.
command.
PEQIA
Status Message
B01PEQOF3,2,1250
B01PEQOFB,1,f , where f is the current setting of
the frequency parameter for the parametric EQ on
output B , band 1. If the frequency parameter of
this filter is set to the same value given in the
example above, then the status message will be
B01PEQOFB,1,1250 .
command except that only one
PEQOA
PEQOA
command.
PEQIA
Status Message
B01PEQOG3,2,-20
B01PEQOGB,1,g , where g is the current
setting of the gain parameter for the parametric
EQ on output B , band 1. If the gain parameter
of this filter is set to the same value given in the
example above, then the status message will be
B01PEQOGB,1,-20 .
command. To
PEQIF
command for more
command. To set all