Query phone output gain.
B01GAINP?

8.144. RING -- Enable or Disable Ring Messages

This command sets or queries the enabled status of the ring message feature. If ring messages are enabled,
a RING status message will be generated each time the connected phone line rings.
This command is a boolean command. See
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description
B01RING1 Enable auto answer mode. B01RING1
B01RING0 Disable auto answer mode. B01RING0
B01RING2 Toggle auto answer mode.
B01RING? Query auto answer mode.

8.145. SGGAIN -- Set Gain of Signal Generator

This command sets the gain of the internal signal generator. The value of SGGAIN specifies the gain in dB
applied to signal generator. A gain of 0 dB produces a signal at nominal level (-20 dB full scale).
This command is an integer command. See
minimum and maximum values for this command are -100 and 20, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
B01SGGAIN6 Set signal generator gain to 6 dB.
B01SGGAIN>3 Increase signal generator gain by 3 dB.
B01SGGAIN? Query signal generator gain.
B01GAINPx , where x is the new value of the
phone output gain. If this command was issued
after the example above, then the status message
would be B01GAINP9 .
Section 6.1
for more information on this type of command.
Status Message
B01RINGx , where x is 0 or 1 depending on the current state of
auto answer mode.
B01RINGx , where x is 0 or 1 depending on the current state of
auto answer mode.
Section 6.2
for more information on this type of command. The
Status Message
B01SGGAIN6
B01SGGAINx , where x is the new value of the
signal generator gain. If this command was issued
after the example above, then the status message
would be B01SGGAIN9 .
B01SGGAINx , where x is the new value of the
signal generator gain. If this command was issued
after the example above, then the status message
would be B01SGGAIN9 .