8.20. AMGNOM -- Set Global Maximum Number of Open Mics for
Bus Automixer
This command sets the global maximum number of open mics (NOM) allowed for the specified bus
automixer. The NOM limit is a global limit, meaning that this applies to all bus automixers with the same
AMBUSID. In contrast, the
EF2241.
The first argument of this command specifies the automixer number (1-2) to adjust. The second argument
specifies the NOM limit (1-64). Even though this is a channel integer command, use of the wildcard for
specifying the automixer number is not supported.
This command is a channel integer command. See
type of command. The minimum and maximum values for this command are 1 and 64, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
Set global NOM for automixer 1 to a
B01AMGNOM13
maximum of 3 mics.
Query current global NOM limit for
B01AMGNOM2?
automixer 2 .

8.21. AMHOLD -- Set Automixer Hold Time

This command sets or queries the hold time (in milliseconds) for both automixers. Note that the hold time is
set globally for both automixers.
This command is an integer command. See
minimum and maximum values for this command are 0 and 5000, respectively.
Set gate threshold for manual
gating threshold to 12 dB for
inputs 1-2 and 15 dB for inputs 3-
4.
Decrease gate threshold for
manual gating threshold by 3 dB
for all input channels.
Query gate threshold for manual
gating threshold for all input
channels.
command is a local limit that applies to the two local automixers in the
AMNOM
B01AMGATET*ÉÉôô
B01AMGATET*abcd , where a-d will each be
between ä and
gate threshold for each input channel. If this
command is issued after the example above, the
status message will be B01AMGATET*ììÉÉ .
B01AMGATET*abcd , where a-d will each be
between ä and
gate threshold for each input channel. If this
command is issued after the example above, the
status message will be B01AMGATET*ììÉÉ .
Section 6.3
and
Status Message
B01AMGNOM13
B01AMGNOM2x , where x is between 1 and 64
depending on the current setting of the global
NOM limit for automixer 2 .
Section 6.2
for more information on this type of command. The
depending on the setting of the
depending on the setting of the
Section 6.2
for more information on this

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vortex EF2241 and is the answer not in the manual?

Questions and answers

Table of Contents