Amlmm -- Set Last Mic On Mode For Specified Automixer - Polycom Vortex EF2241 Programming Manual

Rs-232 command set
Hide thumbs Also See for Vortex EF2241:
Table of Contents

Advertisement

This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
B01AMHOLD500 Set automixer hold time to 500 ms.
Increase automixer hold time by 500
B01AMHOLD>500
ms.
Query automixer hold time.
B01AMHOLD?

8.22. AMLMM -- Set Last Mic On Mode for Specified Automixer

This command sets "last mic on" mode for the specified automixer. The first argument specifies which
automixer (1-2) The second parameter specifies the operation of "last mic on" mode and can be one of the
following:
0 - last mic mode is off
1 - manual (use a specific mic)
2 - automatic (the last gated mic remains on)
If the AMLMM command sets "last mic on" mode to manual, but the last mic number (AMLMN) is set to a
microphone that does not belong to the specified automixer, then the AMLMM command will fail and
ERROR#042 will be generated. See the
Section 3.5
for more information on dependencies within the automixer commands.
Even though this is a channel integer command, use of the wildcard character for specifying the automixer
number is not supported.
This command is a channel integer command. See
type of command. The minimum and maximum values for this command are 0 and 2, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example
Description
B01AMLMM10 Disable "last mic on" mode for automixer 1.
Set "last mic on" mode to manual for
B01AMLMM21
automixer 2 .
Set "last mic on" mode to automatic for
B01AMLMM12
automixer 1.
Status Message
B01AMHOLD500
B01AMHOLDx , where x is between 0 and 5000
depending on the current AMHOLD setting. If this
command is issued after the above example, then
the status message will be B01AMHOLD1000
B01AMHOLDx , where x is between 0 and 5000
depending on the current AMHOLD setting. If this
command is issued after the above example, then
the status message will be B01AMHOLD1000
command for more information on error messages. See
ERROR
Section 6.3
and
Section 6.2
for more information on this
Status Message
B01AMLMM10
B01AMLMM21
B01AMLMM12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vortex EF2241 and is the answer not in the manual?

Table of Contents