Tc1 - Top Call 1 Setup; Top - Top Floor Setup; Ucm - Up Call Mask Setup; Uc1 - Up Call 1 Setup - ECD 100-194 EN81 Manual

Table of Contents

Advertisement

E E P R O M S E T T I N G S
40: 01000000 (Level 2)
20: 00100000 (Level 3)
08: 00001000 (Level 5)
01: 00000001 (Level 8)
TC1 – Top Call 1 setup
Extension of TCC
80: 10000000 (Level 9)
40: 01000000 (Level 10)
20: 00100000 (Level 11)
10: 00010000 (Level 12)

TOP - Top floor setup

Set value to number floors served. (02 to 0c valid values).
Lift resets to "TOP" value when TSL limit is activated.
02: 00000010 (Level 2)
03: 00000011 (Level 3)
04: 00000100 (Level 4)
05: 00000101 (Level 5)
06: 00000110 (Level 6)
07: 00000111 (Level 7)
08: 00001000 (Level 8)
09: 00001001 (Level 9)
0a: 00001010 (Level 10)
0b: 00001011 (Level 11)
0c: 00001100 (Level 12)

UCM - Up Call Mask setup

This setting lets you define the UP call floors which the lift can serve.
With this setting you may disable UP hall calls to floors not allowed.
Up calls allowed for this lift only.
80: 10000000 (Level 1u)
C0: 11000000 (Level 1u,2u)
E0: 11100000 (Level 1u,2u,3u)
F0: 11110000 (Level 1u,2u,3u,4u)
F8: 11111000 (Level 1u,2u,3u,4u,5u)
FC: 11111100 (Level 1u,2u,3u,4u,5u.6u)
FE: 11111110 (Level 1u,2u,3u,4u,5u,6u,7u)
FF: 11111111 (Level 1u,2u,3u,4u,5u,6u,7u,8u)
UC1 – Up Call 1 setup
Extension of UCM
80: 10000000 (Level 9u)
C0: 11000000 (Level 9u,10u)
E0: 11100000 (Level 9u,10u,11u)
UIM – UnIntended Movement testing
For Hydraulic lifts only
The EN81:20 UIM requirements for hydraulic lifts, are met in the design of this controller when an external door
lock valve is fitted and tested as per the UIM 100-194 hydraulic testing below.
UIM 100-194 hydraulic testing.
UIM shall stop car movement away from UIM zone below with the doors not closed as a result of any single failure
24