 RUP
Running up
 SAF
Lost safety circuit. See SAF input

LCD Door Modes

02u
NOR RUP
ECD Aust. V-6.05
 <>
Doors opening
 []
Doors open
 ><
Doors closing
 ][
Doors closed
 -bad
Doors fully closed but car door/door locks not made. See DFC input
 -fail
Doors failed on DOP or DCP. See DFC/DFO input
- -
Doors on other control. ie – Inspection.

LCD Control Buttons

There are 9 push buttons beneath the LCD screen;
02u
ECD Aust. V-6.05
Forward
Backward
Up
Down
 ENT
Enter. Enter a changed parameter value
 TOP CALL enters a car call to Eeprom TCC setting
 INTER
enters a car call to Eeprom CIM setting
 BOT CALL enters a car call to Eeprom BCC setting
 UIM
is the reset button when lift fails on Unintended Movement

LCD Display Options

Use the Forward, Backward, Up and Down buttons to cycle through the available options
The Door Mode is shown at the top right of the LCD display.
][
The above example shows the doors closed
NOR RUP
ENT
][
TOP CALL INTER BOT CALL UIM