RUP
Running up
SAF
Lost safety circuit. See SAF input
LCD Door Modes
02u
NOR RUP
ECD Aust. V-6.05
<>
Doors opening
[]
Doors open
><
Doors closing
][
Doors closed
-bad
Doors fully closed but car door/door locks not made. See DFC input
-fail
Doors failed on DOP or DCP. See DFC/DFO input
- -
Doors on other control. ie – Inspection.
LCD Control Buttons
There are 9 push buttons beneath the LCD screen;
02u
ECD Aust. V-6.05
Forward
Backward
Up
Down
ENT
Enter. Enter a changed parameter value
TOP CALL enters a car call to Eeprom TCC setting
INTER
enters a car call to Eeprom CIM setting
BOT CALL enters a car call to Eeprom BCC setting
UIM
is the reset button when lift fails on Unintended Movement
LCD Display Options
Use the Forward, Backward, Up and Down buttons to cycle through the available options
The Door Mode is shown at the top right of the LCD display.
][
The above example shows the doors closed
NOR RUP
ENT
][
TOP CALL INTER BOT CALL UIM