Lok - Number Of Door Locks; Lob - Lobby Floor Setup; Lo1 - Lobby 1 Setup; L.# - Lift Number Setup - ECD 100-194 EN81 Manual

Table of Contents

Advertisement

E E P R O M S E T T I N G S
LCK and COD must both be set to default values to allow other parameters to be adjusted.
See also EEPROM setting COD
LCK default. 67: 01100111
COD default. 89: 10001001
LOK – number of door LOcKs
For dual door lock installations (primary and secondary locks) set LOK EEPROM setting to "02"
For single door lock installations (primary locks only) place permanent bridge across LOCKS 2
and set LOK EEPROM setting to "01"
See also Inputs-Outputs LCK2

LOB - LOBby floor setup

Master zoning floor.
This signal sets the master zoning floor. After the zone time period as defined by ZTM, a lift shall zone to floor
defined by LOB, if unoccupied. If LOB floor is occupied then the lift shall alternatively zone to ZON floor.
A lift shall zone to floor defined by LOB and ignore ZON, when working in simplex.
LOB must be set to the same value in all lifts belong to the group.
00: 00000000 (No zoning). To disable zoning set "LOB" and "ZON" to "00".
80: 10000000 (Level 1)
40: 01000000 (Level 2)
20: 00100000 (Level 3)
10: 00010000 (Level 4)
08: 00001000 (Level 5)
04: 00000100 (Level 6)
02: 00000010 (Level 7)
01: 00000001 (Level 8)
See also Input - Output, NDG, NR
See also EEPROM setting PRK, ZON

LO1 - LObby 1 setup

Extension of LOB.
80: 10000000 (Level 9)
40: 01000000 (Level 10)
20: 00100000 (Level 11)
10: 00010000 (Level 12)

L.# - Lift Number setup

Lift number setup.
Example: In a 2 car group, one lift is set to 01 and the other set to 02.
Set value to the lift number. (01 to 06 valid values.)
01: 00000001 (Lift 1)
02: 00000010 (Lift 2)
03: 00000011 (Lift 3)
04: 00000100 (Lift 4)
05: 00000101 (Lift 5)
06: 00000110 (Lift 6)
See also Inputs-Outputs #.L
MOD – MODe Inputs setup
Enables 5 MODE inputs to be inverted
01: 00000010 CFSS. Car Fire Service Start input inverted
02: 00000010 CFS. Car Fire Service input inverted
04: 00000100 HFS. Hall Fire Service input inverted
19