E E P R O M S E T T I N G S
08: 00001000 IND. Independent operation input inverted
80: 10000000 PRV. Proving input inverted
C0: 00001100 IND & HFS inputs inverted
MSL – Magnet SLowing type
Sets the slowing/counting type.
00: 00000000 MSU/MSD magnet slowing.
01: 00000001 Pulse slowing.
02: 00000001 Pulse slowing. 2 BSL limit switches required.
03: 00000011 Pulse slowing with no position update. Requires circuit to remove DZ input above levelling speed
See also Section 6: Motion – EEPROM MSL setting "00", "01", "02" and "03"

NR - Door Nudging setup

Sets the door nudging feature on or off. (Nudging time is preset)
Sets "NDG" output on or off to control the floor passing tone
00: 00000000 No door nudging or passing tone. Sets EDP/OS time to 30 secs
01: 00000001 Door nudging only
02: 00000010 Door nudging and passing tone
03: 00000011 Passing tone only. Sets EDP/OS time to 30 secs
04: 00000100 Sets EDP/OS time to 180 secs
See also Input - Output, NDG, NR

PI - Position Indication setup

Position Indication output type
This setting changes the PI transistor output sequence to the following values
00: 00000000 "Decimal outputs"
01: 00000001 "Binary outputs"
02: 00000010 "Gray code outputs"
PRK – PaRK / zone with doors open
Sets the doors to stay open or stay closed after zoning
00: 00000000 - Zones to floor and doors remain closed
01: 00000001 - Zones to floor and doors remain open. Eg. train platform
See also EEPROM setting LOB, ZON
RD1 – Rear Doors 1 setup, levels 1-8
This sets the levels for the rear doors to operate via DZR output on levels 1-8
DZR relay is used for the rear door control and is switched by DZR output
RD1 eliminates the need for a rear door/DZR sensor in the shaft
May be used in conjunction with FD1 and SD1 for selective rear door operation
See also EEPROM setting FD1, SD1
Controller switches DZR output to 0V when lift at level 1 or 3 in example below
FD1 A0: 10100000 (Level G and level 2 have front doors)
RD1 50: 01010000 (Level 1 and level 3 have rear doors)
FLOOR DESIG.
3
2
1
G
FRONT DOORS
2 (front) 3C, 3U, 3D
G (front) 1C, 1U
REAR DOORS
3 (rear) 4C, 4D
1 (rear) 2C, 2U, 2D