Sign In
Upload
Manuals
Brands
ECD Manuals
Controller
100-194 EN81
ECD 100-194 EN81 Manuals
Manuals and User Guides for ECD 100-194 EN81. We have
1
ECD 100-194 EN81 manual available for free PDF download: Manual
ECD 100-194 EN81 Manual (80 pages)
Brand:
ECD
| Category:
Controller
| Size: 2.31 MB
Table of Contents
Table of Contents
3
Section 1: Safety Regulations & Introduction
6
Following Operating Instructions
6
Obligations of Operator
6
Obligations of Personnel
6
Hazards Associated with the Equipment
7
Warranty and Liability
7
1.2.6 Organizational Measures
7
1.2.7 Protective Equipment
7
1.2.8 Informal Safety Measures
8
1.2.9 Training of Personnel
8
1.2.10 Machine Controls
8
1.2.11 Safety Measures During Normal Operation
8
1.2.12 Hazards Caused by Electric Power
8
1.2.13 Hazards Caused by Hydraulic Power
9
Special Danger Areas (Examples)
9
1.2.15 Controller Installation Environmental Requirements
9
Introduction
10
Testing RCD / RCBO on 110Vac Safety Circuit
10
Section 2: EEPROM (Lift Parameter) Settings
11
EEPROM Version 6.04 Parameter Summary
12
EEPROM Definitions (Full Description)
15
ADO - Advanced Door Opening Setup
15
ALP - Auxiliary Leveling Pump Operation Setup
15
ANS - Anti Nuisance Setup
15
BCC Bottom Car Call Setup
15
BOT - Bottom Floor Setup
15
BST - Brake Switch Time
15
BSW - Brake Switch Polarity
16
CIM - Car Call Intermediate Setup
16
CI1 - Car Intermediate 1 Setup
16
CCM - Car Call Mask Setup
16
CC1 - Car Call 1 Setup
17
CNT - CNT Input Setup
17
COD - Parameter Lockout Function
17
DCM - down Call Mask Setup
17
DC1 - down Call 1 Setup
17
DLI - Door Limit Invert Setup
17
DLM - Door Limit Setup
18
DPT - Door Protection Time
18
DRV - Drive Type Setup
18
DT - Door Time Close Setup
19
DTC - Door Time Car Call Close Setup
19
DTH - Door Time Hall Call Close Setup
19
DTL - Door Time Lobby Call Close Setup
19
DTR - Door Time Recall
19
FD1 - Front Doors 1 Setup, Levels 1-8
20
FD2 - Front Doors 2 Setup, Levels 9-12
20
HFS - Hall Fire Service Return Floor Setup
20
HF1 - Hall Fire 1 Setup
20
HRF - Hospital / Hall Recall Floor
20
HR1 - Hospital / Hall Recall 1 Setup
20
LCK - Parameter Lockout Function
20
LOK - Number of Door Locks
21
LOB - Lobby Floor Setup
21
LO1 - Lobby 1 Setup
21
L.# - Lift Number Setup
21
MOD - Mode Inputs Setup
21
MSL - Magnet Slowing Type
22
NR - Door Nudging Setup
22
PI - Position Indication Setup
22
PRK - Park / Zone with Doors Open
22
RD1 - Rear Doors 1 Setup, Levels 1-8
22
RD2 - Rear Doors 2 Setup, Levels 9-12
23
RPT - Run Protection Timer / Motor Run Timer Setup
23
RTM - Run Time Short Floor Run Setup
23
SD1 - Selective Rear Doors Setup, Levels 1-8
24
SD2 - Selective Rear Doors Setup, Levels 9-12
24
SDX - Star Delta Exchange Time Setup
24
SDX - VF Drive Setting 06,07,08 Brake Drop Time
24
SFR - Short Floor Run Setup
24
SF1 - Short Floor 1 Setup
25
Stf - Start Fast
25
Stm - Start Medium
25
Slf - Slow Fast
25
Slm - Slow Medium
25
SSD - Soft Start Drive
25
ST2 - Star Delta 2 Setup
25
ST2 - VF Drive Setting 06,07,08 End Run Time
25
TCC - Top Car Call Setup
25
TC1 - Top Call 1 Setup
26
TOP - Top Floor Setup
26
UCM - up Call Mask Setup
26
UC1 - up Call 1 Setup
26
UIM - Unintended Movement Testing
26
XTM - Extend Run Time Short Floor Run
28
ZON - Zoning Floor Setup
28
ZO1 - Zoning 1 Setup
29
ZTM - Zoning Time Setup
29
L - Number of Lifts Setup
29
Section 3. Group
30
Group Connections and Communication
30
Group Checks
31
Group / Duplex Faults
31
Section 4. Inputs - Outputs, Onboard Switches, Push Buttons, Terminals
32
BKS1 - Brake Switch 1 Input
32
BKS2 - Brake Switch 2 Input
32
BRK - Brake Relay Output
32
BSL - Bottom Slowing Limit Input
33
BYPASS Onboard Switch
33
BPAV - Bypass Switch Audio Visual Alert Output
33
CFS - Car Fire Service Input
33
CFSS - Car Fire Service Start Input
33
CG - Car Gate Input
33
CG Relay - Car Gate Relay
33
CGBP Relay
34
CGM LED - Car Gate Monitoring LED
34
CLP - Car Light and Power Output
34
COR - Correction Run Output
34
DC - Door Close Relay Output
34
DCB - Door Close Button Input
34
DDN - Direction down Output
34
DF - down Fast Relay Output
34
DFC - Door Fully Closed Input
34
DFO - Door Fully Open Input
37
DN - down Relay Output
38
DO - Door Open Relay Output
38
DOB - Door Open Button Input
38
DOOR Disable Onboard Toggle Switch
39
DS - down Slow Relay Output
39
DUP - Direction up Output
39
DZ - Door Zone Input
39
DZR - Door Zone Rear Output
39
DZ Relay
39
EDP - Electronic Door Protection Input
39
EP - Emergency Power Input
40
EQK - Earthquake Detection Input. (Siesmic or Counterweight Displacement Switch)
40
HBS - Hall Button Stop
40
HCB - Hall Call Bypass
40
HFS - Hall Fire Service Input
41
HRI - Hospital / Hall Recall Input
41
HRO - Hall (Hospital) Recall Output
41
IDN - Inspection down Input
41
IND - Independent Service Input
41
INSP - Inspection Control Input
41
INSP Controller Onboard Switch
42
INSP COM Onboard Push Button
42
INSP DN Onboard Push Button
42
INSP up Onboard Push Button
42
IRO - Inspection Relay Output
42
IUP - Inspection up Input
42
LCK1 - Lock 1 Input
42
LCK1M LED - LCK1 Monitoring LED
42
LCK1 Relay
42
LCK2 - Lock 2 Input
43
LCK2 Relay
43
LEV Relay
43
LOCK VALVE SWITCH Onboard Toggle Switch
43
L1BP Relay
43
L2BP Relay
43
MSD - Magnetic Switch down Input
43
MSD Relay
44
MSU - Magnetic Switch up Input
44
MSU Relay
44
M1 - M1 Output Terminal
44
M3 - M3 Input
45
M4 - M4 Terminal
45
N - Neutral Terminal
45
NDG - Nudging Buzzer Output
45
NR - Nudging Relay Output
45
OIL - OIL Overheat Input
45
OS - out of Service Output
45
OVL - Overload Input
46
OVLO - Overload Output
46
PAWL - PAWL Device Output
46
PCOM - Pit Inspection Common Input
46
PINS - Pit Inspection Input
46
PRES - Pit Inspection Reset Input
47
PRK - Parking Input
47
PRV - Proving Circuit Input
47
PULSE - PULSE Counting Input
47
PWLE - Pawl Device Extended Input
47
PWLR - Pawl Device Retracted Input
47
SAF - Safety Circuit Input
47
Sin1 - Input
47
Sin2 - Input
48
Sin3 - Input
48
SO1 - Output
48
SO2 - Output
48
SO3 - Output
48
SO4 - Output
48
SP1 - Spare Relay Output 1
48
SP2 - Spare Relay Output 2
48
SP3 - Spare Relay Output 3
48
SP4 - Spare Relay Output 4
48
TSL - Top Slowing Limit Input
49
UD - up Dn Relay Output
49
UF - up Fast Relay Output
49
UIM - Unintended Movement Output
49
UP - up Relay Output
49
US - up Slow Relay Output
49
1C/12C - Car Call Input / Output
49
2D/12D - down Hall Call Input / Output
49
1P/12P - Position Output
50
1U/11U - up Hall Call Input / Output
50
Section 5. Liquid Crystal Display (LCD)
51
LCD Position & Direction
51
LCD Lift Mode
51
LCD Lift Status
52
LCD Door Modes
53
LCD Control Buttons
53
LCD Display Options
53
LCD Fault Log
55
Section 6. Motion
57
Motion Control Outputs
57
Drive Settings and Their Output Status
57
Counting Method "00" - Magnet Counting
66
Counting Method "01" - Pulse Counting
68
Counting Method "02" - Pulse Counting
75
Counting Method "03" - Pulse Counting
77
Section 7: Faults - Fault Finding
78
On Board Fuse Blows
78
Testing 24Vdc
78
Testing RCD / RCBO on 110Vac Safety Circuit
78
Doors Do Not Open
78
Doors Don't Open at Terminal Floors
78
Lift Gets out of Step
79
Lift Performs Correction Runs Intermittently
79
Lift Does Not Answer Car Calls
79
Lift Does Not Answer Hall Calls
79
Lift Misses Calls
79
Red3 LED Is Not Blinking
79
Advertisement
Advertisement
Related Products
ECD 100-181
ECD Brake Board
ECD OvenRIDER NL2+
ECD Categories
Measuring Instruments
Controller
Dryer
Transmitter
Data Loggers
More ECD Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL