UIM FAIL:
If, while performing a UIM TEST, the lift continues to travel beyond the UIM zone and travels beyond DZ, the
controller will shut down and UIM Test: Fail shall be displayed on the screen.
Investigate as to why the lift did not stop within the UIM zone.
Press the UIM button to return the lift to UIM Test.
To re test, move the lift back to floor level using the On-Board Inspection
buttons and press BOT CALL.
When UIM Testing is completed, press the UIM button to return the lift to UIM Test.
Change Eeprom setting UIM back to FF
Turn off controller inspection and return lift to service.
XTM – Extend run time short floor run
Nb: DRV must be set to a traction lift setting.
If a short floor exists where the lift starts slowing prior to reaching full speed, a long creep into floor may occur.
RTM setting, in conjunction with XTM setting, reduces this long creep time by holding in the fast speed relay for a
defined time (XTM) after the initial slowing point.
Setting RTM. – Look at RAM address R:72. (Motion Timer).
When performing the shortest floor run take note of the highest value R:72 reaches (in hex). Add approx. 5 (in hex)
to this value and set RTM to this value.
If slowing is obtained before the value in RTM is reached, the fast speed relay (UF or DF) will be held up for extra
time as defined by XTM.
Set XTM to 20. If the lift fails to slow down to levelling speed before reaching the floor, (fast speed relay is being
held up too long) reduce XTM value. If there is still too much creep (fast speed relay is being held up not long
enough) increase XTM time. Continue until desired result is obtained.

ZON - Zoning floor setup

ZON is only used in duplex configurations
After the zone time period as defined by ZTM, a lift shall zone to floor defined by LOB. If LOB floor is occupied
then the lift shall alternatively zone to ZON floor
Recommend to set ZON to the same value for all lifts in the group
A lift shall zone to the floor defined by LOB and ignore ZON, when working in simplex
See also EEPROM setting LOB, PRK
00: 00000000 (No zoning). To disable zoning set "LOB" and "ZON" to "00".
80: 10000000 (Level 1)
40: 01000000 (Level 2)
20: 00100000 (Level 3)
10: 00010000 (Level 4)
08: 00001000 (Level 5)
04: 00000100 (Level 6)
02: 00000010 (Level 7)
02-
NOR IDL
R:70
00 OA
00
To access R:72 on the LCD see also Section 5: LCD
][
Display Options
14
R: 72 shown in red at left.
26
??-
UIM IDL
--
UIM 01
: 00000001
UIM Test:
Fail
Unintended Movement