ECD 100-194 EN81 Manual page 13

Table of Contents

Advertisement

E E P R O M S E T T I N G S
Setting example: MOD 02: 00000010 (CFS input inverted)
CNT CNT inputs
Setting example: CNT 02: 00000010 (DOB input inverted)
CIM Intermediate floor car call for "INTER" button on the circuit board
Setting example: CIM 23: 00100011 (Set to Levels 3, 7 and 8)
CI1
Intermediate floor car call extension. Ext. of CIM
Setting example: CI1 40: 01000000 (Set to Level 10)
LOK Single or Dual Lock circuit.
Setting example: LOK 01: 00000001 (Single door locks)
Setting example: LOK 02: 00000001 (Dual door locks)
RPT Run protection timer
Setting example: RPT 14: 00010100 (20s). Min 14, Max 2D
DRV Drive control type.
Setting example: DRV 02: 00000010 (3010/2CH/S block)
ST2
Star Delta time
Setting example: ST2 08: 00001000 (= 800ms)
SDX Star Delta Exchange time.
Setting example: SDX 01: 00000001 (= 100ms)
MSL Magnet slowing type.
Setting example: MSL 00: 00000000 (MSU/MSD slowing)
RTM Extend run time. If slowing is obtained less than this time, then add the value
of XTM on before dropping high speed.
Setting example: RTM A5: 10100101
XTM Extend run time. If a short floor is determined by RTM then add XTM time on
before dropping high speed.
Setting example: XTM 20: 00100000 (extended fast speed run time by 20)
StF
Start Fast. Number of pulses it takes to reach fast speed.
StM
Start Medium. Number of pulses it takes to reach medium speed.
SlF
Slow Fast. Number of pulses it takes to slow from fast speed.
SlM
Slow Medium. Number of pulses it takes to slow from medium speed.
BST
Brake Switch Time. Time for BKS1 and BKS2 inputs to be initiated
Setting example: BST 13: 0001001 (3s)
DPT Door Protection Time. Maximum time allowed for doors to reach fully open
Setting example: DPT FF: 11111111 (25s)
UIM UnIntended Movement testing
Setting example: UIM 01: 00000001 UIM Test enabled
BSW Brake Switch Polarity
Setting example: BSW 01: 00000001 (normally open brake contact)
DLM Door limit mask.
Setting example: DLM 00: 00000000 (Single doors)
DLI
Door limit invert.
Setting example: DLI 00: 00000000 (Limits not inverted)
NR
Nudging Relay for door nudging/Passing tone
Setting example: NR 00: 00000000 (Nudging off.)
ADO Advanced Door Opening.
Setting example: ADO 00: 00000000 (off )
DTC Door time car call. Time doors stay fully open after answering a car call
Setting example: DTC 32: 00110010 (5000ms, "5 seconds")
DTH Door time hall call. Time doors stay fully open after answering a hall call
Setting example: DTH 32: 00110010 (5000ms, "5 seconds")
DTL Door time lobby. Time doors stay fully open after answering a "LOB" call
Setting example: DTL 32: 00110010 (5000ms, "5 seconds")
ANS Anti Nuisance EDP.
MSL 01: 00000001 (Pulse slowing)
11

Advertisement

Table of Contents
loading

Related Products for ECD 100-194 EN81

Table of Contents