E E P R O M S E T T I N G S
If the input is not detected within the specified time (setting 01-05) the lift shall stop immediately and display BST
in LCD Lift Status.
Setting example 11-15:
(stop next floor)
If the input is not detected within the specified time (setting 11-15) the lift shall stop at the next available floor,
open and close the doors and display "BST" - BRK Lifting Timeout, in the LCD Lift Status. Door open button will
still operate.
BST is a fatal error. Reset is only via a processor POR. BST error shall be disabled when the lift is on inspection
Nb: Default BST setting shall be "13" (stop at next floor). Any other setting than above will default to setting "01"
BSD and BST errors shall be disabled when the lift is on inspection
See also Input - Output, BKS1, BKS2
See also LCD lift status BSD, BST.
See also EEPROM setting BSW
BSW – Brake SWitch Polarity
Used to set brake switch inputs to normally open or closed:
00: 00000000 Normally closed brake contact. Brake not energised, BKS1 and BKS2 inputs must be on
01: 00000001 Normally open brake contact. Brake not energised, BKS1 and BKS2 inputs must be off
Nb: Default BSW setting shall be "01" (Normally open contact)
See also Input - Output, BKS1, BKS2

CIM - Car call InterMediate setup

The controller shall enter a car call(s) to this setting when the "INTER' button on the circuit board is pressed
40: 01000000 (Level 2)
20: 00100000 (Level 3)
30: 00110000 (Level 3 and 4)
01: 01010101 (Level 2,4, and 8)

CI1 - Car Intermediate 1 setup

Extension of CIM
80: 10000000 (Level 9)
10: 00010000 (Level 12)

CCM - Car Call Mask setup

Floors allowed. (MASK). For this lift only.
This setting lets you define the floors which the lift can serve via car calls.
Set bits to a "1" car call allowed or a "0" for not allowed.
C0: 11000000 (1c,2c)
E0: 11100000 (1c,2c,3c)
F0: 11110000 (1c,2c,3c,4c)
F8: 11111000 (1c,2c,3c,4c,5c)
FC: 11111100 (1c,2c,3c,4c,5c,6c)
FE: 11111110 (1c,2c,3c,4c,5c,6c,7c)
FF: 11111111 (1c,2c,3c,4c,5c,6c,7c,8c)
Note: This feature is not to be used to place a floor on security, as this would also disable the car calls in Fire
03: 00000011 = 3s
04: 00000100 = 4s
05: 00000101 = 5s
11: 00010001 = 1s
12: 00010010 = 2s
13: 00010011 = 3s
14: 00010100 = 4s
15: 00010101 = 5s