Section 5. Liquid Cr ystal Display (LCD)
LCD Info, Modes, Status, buttons and navigation, Fault Log
LCD contrast is set via "Contrast" POT located to the upper left of LCD
LCD Position & Direction
02u
NOR RUP
][
ECD Aust. V-6.05
LCD Lift Mode
02u
NOR
RUP
][
ECD Aust. V-6.05
List of Lift Modes;
CFS
Lift on Car Fire Service
COR Lift performing a CORrection run due to loss of position
DDO Door Disable Open. Toggle switch provided on board
EP
Lift on Emergency Power
EQK EarthQuaKe detected. See EQK input
HCB Hall Call Bypass
HFS
Lift on Hall Fire Service
HR
Lift on Hospital / Hall Recall
IND
Lift on INDependent service
INS
Lift on INSpection
LRN LeaRNing floor operation in progress
NOR Lift on NORmal operation
NPT
No Pulse Time out. Fatal error. See Section 6, counting method 01, NPT
OIL
Hydraulic OIL overheat. See OIL input
OVL Lift OVerLoad sensor triggered. See OVL input
PIT
Lift on PIT inspection
PRK
Lift on Park
UIM
UnIntended Movement. Non-commanded movement of the lift. See UIM input
ZON Lift ZONed/zoning to floor
The lift position is shown in the top left of the LCD display, followed by the
current demand direction.
The above example shows the lift on the 2
The lift mode is shown in the top left centre of the LCD display.
The above example shows the lift on Normal
49
Section
nd
floor with an up direction