Cc1 - Car Call 1 Setup; Cnt - Cnt Input Setup; Cod - Parameter Lockout Function; Dcm - Down Call Mask Setup - ECD 100-194 EN81 Manual

Table of Contents

Advertisement

E E P R O M S E T T I N G S
Service and other modes of emergency operation.

CC1 - Car Call 1 setup

Extension of CCM
80: 10000000 (9c)
C0: 11000000 (9c,10c)
E0: 11100000 (9c,10c,11c)
F0: 11110000 (9c,10c,11c,12c)
Note: This feature is not to be used to place a floor on security, as this would also disable the car calls in Fire
Service and other modes of emergency operation
CNT – CNT input setup
Enables 3 CNT inputs to be inverted
00: 00000000 No inputs inverted.
01: 00000001 DCB. Door close input inverted
02: 00000010 DOB. Door open input inverted
04: 00000100 EDP. EDP input inverted
06: 00000110 DOB and EDP inputs inverted
COD – parameter lockout function
To stop unauthorised adjustments to the EEPROM parameters and to also disable the "Clear fault log" function
(see Section 5 – LCD Fault Log), the COD and LCK parameters are used
COD and LCK must be both set to the default values below to allow other parameters to be adjusted
See also EEPROM setting LCK
COD default. 89: 10001001
LCK default. 67: 01100111

DCM - Down Call Mask setup

Down hall calls allowed for this lift only
This setting lets you define the DOWN floors which the lift can serve via DOWN HALL CALLS
With this setting you may disable DOWN hall calls to floors not allowed
Set bits to a "1" hall call allowed or a "0" for not allowed
40: 01000000 (2d)
60: 01100000 (2d,3d)
70: 01110000 (2d,3d,4d)
78: 01111000 (2d,3d,4d,5d)
7C: 01111100 (2d,3d,4d,5d,6d)
7E: 01111110 (2d,3d,4d,5d,6d,7d)
7F: 01111111 (2d,3d,4d,5d,6d,7d,8d)
DC1 – Down Call 1 setup
Extension of DCM
80: 10000000 (9d)
C0: 11000000 (9d,10d)
E0: 11100000 (9d,10d,11d)
F0: 11110000 (9d,10d,11d,12d)

DLI - Door Limit Invert setup

DLI is only valid when DLM is set to 00, 03 , 04 or 06. See also EEPROM setting DLM.
DLI setting is used to invert the DFO and DFC inputs when normally open (n/o) door limit contacts are used.
DLI: 00 "Limits not inverted."
DLI: 01 "Limits inverted." Any setting other than 00 shall default to inverted limits.