E E P R O M S E T T I N G S
Set to the number of times a car call is answered without EDP activation before calls are cancelled.
SSD Soft Starter Drive setting
Setting example: SSD 01: 00000001. Hydraulic lift with Soft Starter motor starting
FD1
Front doors 1-8 mask.
Setting example: FD1 F0: 11110000 (Front doors 1-4)
FD2
Front doors 8-16 mask.
Setting example: FD2 00: 00000000
RD1
Rear doors 1-8 mask.
Setting example: RD1 08: 00001000 (Rear doors 5)
RD2
Rear doors 8-16 mask.
Setting example: RD2 00: 00000000
SD1
Selective rear doors 1-8 mask.
First floor of selective front/rear doors.
Setting example: SD1 10: 00010000 (Levels 4 & 5 selective)
SD2
Selective rear doors 9-16 mask.
First floor of selective front/rear doors.
Setting example: SD2 10: 00010000 (Levels 12 & 13 selective)
DTR Once the lift arrives at the HR floor, the doors shall remain open for the time set as per DTR
Setting example: DTC 32: 00110010 (5000ms, "5 seconds")
HRF Hospital/Hall Recall Floor
Setting example: HRF 40: 01000000 (Set to Level 2)
HR1
Hospital/Hall Recall Floor extension. Ext. of HRF
Setting example: TC1 40: 01000000 (Set to Level 10)
PRK Park/Zone with doors closed/open. Set to 00 – doors closed.
ALP Auxiliary Leveling Pump. Turns on Auxiliary Leveling Pump, for Up Re Level operation.
Setting example:- ALP FF:11111111 (No Auxiliary pump Re-level.)
---
Spare
---
Spare
PI
Position Indication
Setting example: PI 00: 00000000 (Decimal outputs.)
DT
Door Time Close Setup (Enable "DTC/DTH cancelling function")
Setting example: DT 01: 00000001 (DTC/DTH cancelling activated)
LCK EEPROM Lock (unlock default 67)
COD Lock Code (unlock default 89)
---
Spare
---
Spare
ALP 01: 00000001 (Re-leveling with Auxiliary pump)