E E P R O M S E T T I N G S
Introduction
1.2.16
The 100-194 lift controller is a 12 stop, simplex or duplex (up to 6 car group), fully collective controller that has been
manufactured to comply with the EN81-20/50 standard.
Processor
Under normal operation;
The red Red3 LED blinks to confirm that the microprocessor is running.
The yellow Yel3 LED comes on to confirm outputs are enabled.
The green Grn3 LED comes on during power up and turns off during normal operation. It will
When re-powering; ensure the lift is off for 10 seconds before turning back on.
On power up, a delay of approximately 2 seconds is given on start up to ensure voltages are stable prior to reading
and writing outputs.
Testing RCD / RCBO on 110vac Safety circuit.
To test the trip operation of an RCD / RCBO supplied with a 110VAC safety circuit, place a 1.2K ohm resistor
between the load side of the RCD / RCBO and earth.
also flash once when a new value has been written in to EEPROM.