Section 2: Eeprom (Lift Parameter) Settings - ECD 100-194 EN81 Manual

Table of Contents

Advertisement

E E P R O M S E T T I N G S

Section 2: EEPROM (Lift Parameter) Settings

EEPROM: How to read LCD and modify settings
The lift Parameters such as number of floors, door, drive and input settings are adjustable using the on-board LCD
and buttons. Parameters are stored in the EEPROM. Each setting has a definition followed by its value in hex
followed by its value in bit format. To adjust see below. For parameter definitions and examples see the proceeding
EEPROM Parameter Summary.
See also: "Section 5. Liquid Crystal Display" for more LCD information
LCD information from the power up state.
To inspect the settings from the power up state,
press the forward ">" button located to the left
below the LCD until the EEPROM setting appears.
Use the up "" and down "" buttons
to scroll through the settings. If you want to change
a setting value, press the enter "ENT" button. * shall
appear on the screen to indicate you are in edit mode.
Now use the up "" and down "" buttons to
change the setting value. When you are at the required
value, press the enter "ENT" button again and the *
shall disappear and new value shall be stored.
01-
NOR IDL
ECD Aust. V-6.05
01-
NOR IDL
BOT: 01:00000001
01-
NOR IDL
TOP:*08:00000010
01-
NOR IDL
TOP: 06:00000010
9