I N P U T S – O U T P U T S
See also Inputs – Outputs CG, CGM

CGBP relay

Onboard Car Gate Bypass relay
CGBP relay pulls up when BYPASS is switched to CGBP
No external relay contacts available – internal use only
Must be a safety relay with FGR contacts. No relay socket provided as only serviceable by ECD
CGM LED – Car Gate Monitoring LED
CG relay and CGBP relay contact internal monitoring point
There is no input terminal connection on the board for CGM
CGM LED turns on when either the internal contacts of CG relay or CGBP relay in the safety circuit are closed
See also Inputs – Outputs CG relay, CGBP relay
See also LCD status – "CGC"
CLP – Car Light and Power output
Darlington Output
CLP output turns on to switch off the car lights after 10 minutes of no demand
Used for driving an external light control relay
As soon as demand for lift returns, CLP output shall turn off
Only applicable when lift is in "NOR" normal mode
COR – COrrection Run output
Darlington Output
COR output turns on when the lift is performing a correction run, to limit the correction run speed
"CORrection run" shall be shown on the LCD screen
Used for driving an external relay, where the contacts may be required for a correction speed input to the drive

DC - Door Close relay output

Door Close relay output contacts used to control door closing operation.
See also Inputs – Outputs DFC

DCB - Door Close Button input

DCB input turns on when the door close button is pressed unless inverted with CNT setting
DCB input turns on to close the doors on Independent Service
DCB cancels door timing on normal operation if DT is set to "01"
Both the door detector EDP and door open button DOB override the DCB inputs
See also Inputs – Outputs CFSS

DDN - Direction DowN output

Transistor Output
Direction down output switches for indication of lift advanced down direction

DF - Down Fast relay output

DF relay output contacts are used to control down fast speed operation
See also Section 6: Motion, for more on the relay operation

DFC - Door Fully Closed input

DFC input must change state when the doors reach the fully closed limit/position
Single Doors:
Input state can be inverted with DLI setting. See DLI in EEPROM settings