S A F E T Y R E G U L A T I O N S & I N T R O D U C T I O N

1.2.13 Hazards caused by hydraulic power.

 Only personnel with special knowledge and experience in the field of hydraulics may work on hydraulic
equipment.
 Before beginning repairs, depressurize system sections and pressure lines which are to be opened.

1.2.14 Special danger areas (examples).

 When on inspection, always ensure either of the common or direction control buttons stops the lift.
 The common button shall break the safety line and the 0V up/down direction input.
 Never place yourself or any party in a position of danger where relying on any single safety measure.
 Automatic machines start without warning. Care must be taken at all times.
Always treat terminals and conductors as dangerous. High voltages may be
superimposed on 0v and 24VDC lines as no reference to ground exists. Always

1.2.15 Controller Installation Environmental Requirements

Controller cabinet must be installed in a location free from;
 Dust and dirt.
 Excessive heat and humidity. Ambient temperature should not exceed 40°C /104°F.
 Excessive vibrations.
 Mist or water
When mounting controller cabinet, ensure it is suitably supported.
WARNING!
meter these points to ensure correct voltage exists.