AE Vario Match™ Match Network, VM 1000/1500 Platform
VarioMatch Match Network
Tuning Ranges
This chapter shows the V arioMatch match network's tuning ranges, using Smith
charts. The figure captions include the number of turns and tap settings for the Smith
chart shown in the illustration. To find the number of turns and tap settings of the load
and tune coils of your unit, see
14-TURN TUNE (SERIES) COIL
Schematic
The tune (series) coil has taps at 4, 6, 8, 10, 12, and 14 turns. These are labeled 1
through 6 in the schematic. The load (shunt) coil has 3 turns, labeled A, B, and C.
These labels are used in the Smith charts.
Lin
(wire)
0-----------0
RF IN
Models 300, 1000, and 1500 coil and inductor schematic; 14 turn
Figure 7-1.
tune coil
57020080-00D
"Physical Specifications Table" on page
Cseries
0
VarioMatch Match Network Tuning Ranges
3-7.
3
2
1
RF OU1
C
7-1