CONNECTING THE VARIOMATCH MATCH NETWORK TO
THE LOAD
To Connect the VarioMatch Match Network to the Load:
1. Review the cabling requirements in
2. Locate the PLASMA/LOAD connector or opening on the bottom or side of your
unit.
► For units with 7/16 DIN socket: Connect one end of a user-supplied coaxial
cable to the PLASMA/LOAD output connector on the match network. Attach
the other end of the coaxial cable to the load.
► For units with MC6 connector: Attach the AB-supplied MC6 plug to one end
of a user-supplied cable or copper strap. Attach the plug to the MC6 PLASMA/
LOAD
the load.
► For units with 6 mm brass fittings: AE supplies the brass ferrule and
compression nut for this fitting. Attach the SERTO
ferrule directly to the user-supplied coil. See the SERTO documentation for
instructions on properly connecting the plug. Attach the plug to the 6 mm brass
PLASMA/LOAD

Connecting AC Input (Mains) Power

&
DANGER:
RISK OF DEATH OR BODILY INJURY. Disconnect and lockout/tagout all
sources of input power before working on this unit or anything
connected to it.
57020080-00D
AE VarioMatch
TM
"Cable Requirements" on page
output
connector. Attach the other end of the cable or copper strap to
output
connector.
Installation, Setup,
and Operation
Match Network, VM 1000/1500 Platform
com l ression
®
5-3.
nut
and
5-11