The second sensor is the phase detector, which measures the phase change compared
to a perfect 50
in series with the coil.
Both magnitude and phase information are fed to the motor drive electronics which
immediately drive the electric motors in the correct direction.
To Operate the VarioMatch Match Network in Automatic Tune Mode:
• With the VarioMatch match network connected to a generator, connect the
VarioMatch match network to AC power and it will tum on in automatic mode.
Note: To operate the VarioMatch match network in automatic tune mode when
connected to a CESAR generator, refer to the CESAR user manual.
If the matching quality
below approximately
unable to match properly and the motors will never stop. This condition indicates that
the VarioMatch match network
Match for Your Load" on page
Manual Tune Mode
In addition to the automatic mode, all V arioMatch match network models can be
controlled manually by means of an external controller. This controller can be the AE
RMC-1 Match Network
five switches.
Manual control is useful when the load isn't known and you must find the most
suitable match. Manual tune mode lets you determine whether matching is possible as
configured and if the match is achieved near the limits of one or both of the variable
capacitors.
In manual tune mode, the automatic tune feature is disabled and the capacitor
positions are controlled through the
network. When the interface signal MANUAL MODE is pulled high, the capacitor
positions follow the signals present on the match
To Operate the VarioMatch Match Network in Manual Tune Mode:
• If the VarioMatch match network is connected to a CESAR generator, see
"Interaction With a Cesar Generator"
and
Controls".
• If the V arioMatch match network is connected to a set of five switches, see
Chapter 4, "Communication Interfaces and
57020080-00D
INTERFACE
AE VarioMatch
n
resistive load. This sensor drives the tune variable capacitor which is
isn't
acceptable and the reflected power cannot be reduced
1
%
of maximum transfer power, the automatic mode will be
isn't
set up correctly for the load (see
5-16).
Controller,
an AE Cesar RF Generator, or an arrangement of
Installation, Setup,
and Operation
INTERFACE.
Match Network, VM 1000/1500 Platform
TM
port on the VarioMatch match
and
Chapter 4, "Communication Interfaces
Controls".
"Set Up the
5-15

Advertisement