Match INTERFACE Using Switches

To construct a simple manual control, wire four normally open momentary switches
for the motor drive and one on/off switch for
below.

Table 4-2. Match INTERFACE switch descriptions

Momentary
Motor
switch
drive
Common connection of all 5 switches (Ground)
Switch 1
motor 1
Switch 2
motor 1
Switch 3
motor 2
Switch 4
motor 2
Switch 5 (on/
Manual/
oft)
Auto
Connect the switch box to the match
should be connected to ground at pin 1 of the D-connector. To avoid a ground loop,
which could result in erratic operation of the remote control, do not
shield to any other ground in the system.
57020080-00D
INTERFACE
AE VarioMatch
TM
I
I
Internal circu
I
I
I
I
I
I
9 1-- - ...
Gnd
Results
run clockwise
run counter
clockwise
run clockwise
run counter
clockwise
Selects Manual or Auto mode
Communication
Interfaces and Controls
Match Network, VM 1000/1500 Platform
try
i
CD4001 B
(NOR Gate)
auto/manual
mode selection as described
INTERFACE
1
decrease C
e
2
nm
increase Cnme
3
decrease C
4
Load
increase C
5
Load
8
using a shielded cable. The shield
connect
Connect to
Pin #
the cable
4-7