Advanced Energy VarioMatch Match Network VM 1000 Platform User Manual page 46

Table of Contents

Advertisement

Advanced Energy
®
Cooling specifications (Continued)
Table 3-6.
Description
Contaminates
Minimum air flow
3-16
Specification
AE recommends the following specifications for the water
used to cool the Navigator match network:
pH between 7 and 9
total chlorine <20 ppm
total nitrate <10 ppm
total sulfate <100 ppm
total dissolved solids <250 ppm
total hardness expressed as calcium carbonate
equivalent maximum 250 ppm
<250ppm
specific resistivity of 2500 Q/cm or higher at 25
total dissolved solids (TDS) as estimated by the
following:
TDS � 640,000/specific resistivity
Note: Do not use deionized water for cooling purposes in
order to prevent corrosion and erosion of cooling
manifolds
120 m
/h
3
Specifications
°
C
(in
Q/cm)
57020080-00D